EPC Certification · Regulation

EPB reform in Brussels: the single calculation method, what changes for homes

On 3 July 2025, the Brussels Government adopted a decree introducing a single calculation method for EPB (energy performance of buildings). In January 2026, Brussels Environment published a summary information sheet on it. Here is what changes for homes, point by point, with the expected effect on the EPC certificate depending on the type of property.

The essentials in 4 points

  • A single calculation method for EPC certificates and for works: for homes, this is the “PER” annex.
  • Electricity weighs less (points 1 and 2): primary energy conversion factor from 2.5 to 1.9, CO₂ emission factor from 395 to 231 g/kWh.
  • Climate change is taken into account (point 3): new climate data reduce net heating demand by about 20%.
  • The entry-into-force date will be set by the Minister, depending on the availability of the new EPB calculation software.

Why a single calculation method?

Until now, EPC certification and EPB works relied on separate calculation methods (those in force in 2025). The decree of 3 July 2025 introduces a single method that can be used for all EPB units in the Region.

In practice, it amends the « Lignes directrices » (guidelines) decree to harmonise the calculation rules, and creates a new « Indicateurs et Exigences PEB » (indicators and EPB requirements) decree that replaces the « Exigences » (requirements) decree. This new text defines the indicators shown on EPC certificates, how they are calculated, and the requirements that apply. Two new annexes describe the method: the PER annex for residential EPB units (homes) and the PEN annex for non-residential units. This article focuses on homes.

When does it come into force?

The changes brought by the single method come into force on a date set by the Minister, taking into account the availability of the new EPB calculation software.

Before / after at a glance

Each change is numbered: the same number is used further down, in the section that explains it (click the number to jump there).

ChangeBeforeAfterImpact on the certificate
1Electricity to primary energy conversion factor
2.5 1.9 VariableThe weight of electricity drops by 24%: favourable to homes that use a lot of electricity. The effect depends on the share of electricity consumed or produced.
2Electricity CO₂ emission factor
395 g/kWh 231 g/kWh ImprovementLower calculated CO₂ emissions for the electricity share of the home.
3Reference climate data
Climate observed between 1958 and 1975 Temperature: average expected climate 2020–2050. Solar radiation: observed average 2000–2020 ImprovementAll homes: net heating demand reduced by about 20% (simulations). Net cooling demand increases.
4Party walls (separation wall), new-build home
No impact on primary energy consumption Actual surroundings of the wall taken into account (max U-value unchanged: 1 W/m²/K) VariableNew-build homes with a party wall. For an existing property, the actual surroundings were already taken into account.
5Clear height counted under a roof
2.10 m 1.50 m ImprovementAttic or sloping-roof homes: primary energy consumption per m² reduced.
6Domestic hot water
Calculated from the home's volume, with a fixed minimum need for small units Calculated from floor area, fixed minimum need removed ImprovementHomes under 64 m². For homes with high ceilings, the calculation no longer depends on ceiling height.
7Electricity produced on site (solar PV, cogeneration)
Deducted from all primary energy consumption, gas included Offsets only electricity consumption (annual balance); no more negative result No improvementHomes with solar panels that also use gas or another energy source: the surplus no longer offsets that consumption.
8Cooling consumption
Counted even without a cooling system if overheating exceeds a threshold (“notional cooling”) Counted only with active cooling; efficiency based on the system ImprovementHomes without active cooling: no more cooling consumption counted.

The new calculation data

12Electricity weighs less

The primary energy conversion factor for electricity goes from 2.5 to 1.9, in line with Commission Delegated Regulation (EU) 2023/807. The effect: the weight of electricity consumption in the primary energy consumption of an EPB unit falls by 24%. The impact on the certificate depends directly on the share of electricity consumed or produced. The CO₂ emission factor for electricity also falls, from 395 to 231 g/kWh, based on Belgian data from the European Commission's reference scenario.

3A more realistic climate for calculations

Since the EPB method was created, calculations have relied on the climate observed between 1958 and 1975. Yet a drift has been observed since the late 1980s: these data are no longer representative of the current and future climate. The new data use, for temperature, an average expected climate between 2020 and 2050 (the most optimistic IPCC scenario, taking into account the Brussels urban heat island), and, for solar radiation, the average observed between 2000 and 2020.

Average outdoor temperature (heating calculations)Old valuesNew values
January3.2 °C4.4 °C
April9.2 °C11.7 °C
July17.6 °C19.8 °C
October11.2 °C12.6 °C

The impact on results is significant: simulations show a reduction of around 20% in net heating demand for residential units, and consequently an increase in net cooling demand.

4Party walls: the actual surroundings count

A separation wall is a wall located on or against a boundary between two cadastral plots. For new construction, the maximum permitted U-value remains 1 W/m²/K. However, the primary energy consumption calculation now takes into account the actual surroundings at the time of the EPB declaration: party walls will therefore have an impact on the result. Note: when certifying an existing property, these actual surroundings were already taken into account.

5Attic spaces: floor area counted better

The measurement code now takes into account areas with a clear height of 1.50 m (instead of 2.10 m) for attic rooms or spaces under a sloping roof. For some homes, notably under the roof, total primary energy consumption is thus divided by a larger floor area, which reduces their consumption per m².

Three major changes to the method

6Domestic hot water: calculated on floor area

Net domestic hot water needs were historically determined from the home's volume. This calculation gave different results for similar homes depending on ceiling height, and was problematic for homes with high ceilings, typical of old townhouses. The new method is based on floor area. The fixed minimum need applied to small units is removed, which works in favour of homes under 64 m².

7Solar PV and cogeneration: only electricity is offset

Previously, the primary energy equivalent of electricity produced on site was deducted from all of the unit's primary energy consumption: gas consumption could thus be virtually offset by solar electricity. From now on, only electricity consumption can be offset by on-site electricity production. Any surplus no longer offsets other energy sources. The deduction is made on an annual balance, and it is no longer possible to obtain a negative primary energy consumption.

8End of “notional cooling”

Until now, cooling consumption was counted even without a cooling system, as soon as the overheating indicator exceeded a certain threshold. With the new method, cooling consumption is only taken into account where there is an active cooling installation, and its efficiency is determined more precisely based on the system's characteristics.

What effect for your home?

A question about your EPC or your project?

KRES carries out residential and public EPC certifications, and also supports you with solar panel installation, batteries and EV charging stations — a single point of contact for your entire energy transition.

Request a quote See pricing

Source: information sheet « Méthode de calcul unique » (January 2026), Brussels Environment, summary presentation of the Brussels-Capital Region Government decree of 3 July 2025 on the calculation of EPC certificate indicators and EPB requirements. View the official document (in French).